ACCESSORIES
ITEM ACCESSORY PART NO. ERVBBLHA SIZE USED WITH
Bryant OneTouch Control KVBCN0101BLT All
Bryant Basic Wall Control KVBCN0101BBS All
Bryant Latent Wall Control KV ACN0101BLC All
6 0 --- M i n u t e T i m e r K i t KV ATM010160M All
Bryant 20--- Minute Push Button KV ATM010120B All
Airflow Measuring Kit KVBAC0101KIT All
Hood (2 required) KV AAC0101HOD All
ACCESSORY DESCRIPTION, SUGGESTED AND REQUIRED USE
Bryant OneTouch Control
Control option choice. Used with all ERVs as a main wall control.
Bryant Basic Wall Control
Control option choice. Can be used with all ERVs.
Bryant Latent Wall Control
Control option choice. Can be used with all ERVs.
60 --Minute Timer Kit
Used with all ERVs, time is adjustable between 10 and 60 minutes.
Bryant 20--Minute Push Button
Used with all ERVs when 20 minute manual operation is required
Airflow Measuring Kit
Start up Balancing Kit, includes Magnehelic Gauge
Hood (2 required)
Used with all ERVs. Exterior intake and exhaust hoods.
Control Description Fan Speed Control Humidistat Control Continuous Mode Intermittent Mode
OneTouch Yes No Yes Yes
Latent Yes Yes Yes Yes
Control features
OneTouch Contr ol:
Allows control of ventilator with the touch of a button. This
control will operate as a main wall control. The OneTouch will
operate the unit in Intermittent Mode (20 minutes per hour),
continuous low speed, continuous high speed, and off.
Latent Control:
Low Exchange Mode—If the relative humidity inside the building
is lower than selected, air exchange would occur with the outside at
high speed. If the relative humidity inside the building is higher
than selected, air exchange would occur with the outside at low
speed. This ensures continuous air exchange for constant air
quality.
Intermittent Mode—If the relative humidity inside the building is
higher than selected, no air exchange would occur and the system
would turn of f. If the relative humidity inside the building is lower
than selected, air exchange would occur with outside at high speed.
this mode is ideal for maintaining the proper humidity level when
the continuous mode cannot.
Automatic Defrost Cycle Featur
es
All models offer a non--electric defrost cycle feature which
prevents frost and ice buildup within the heat recovery core. When
the outside air temperature falls below 23_F(--5_C) it is
electronically sensed and the dampers close the outside air ports.
This allows warm indoor air to recirculate within the heat recovery
core. The frequency of this cycle increases as the outside air
temperature decreases.
Model
25_F
( --- 5 _C)
4_F T O --- 1 7 _F
( --- 1 5 . 6 _C T O --- 2 7 . 3 _C)
B E L O W --- 1 8 _F
( --- 2 7 . 8 _C)
DEFROST* EXCHANGE{ DEFROST* EXCHANGE{ DEFROST* EXCHANGE{
ERVBBLHA 10 Minutes 60 Minutes 10 Minutes 30 Minutes 10 Minutes 20 Minutes
* All defrost times are in the standard mode (as shipped)
{ Time between defrost when within specified temperature range
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
E2007 Bryant Heating & Cooling Systems 7310 W. Morris St. India napolis, IN 46231 Printed in U.S.A. Edition Date: 07/07
Replaces: NEW
Catalog No: PDSER