1
Installation, Start--Up, and
Operating Instructions
GAPA
PERFECT AIRT PURIFIER
SIZES 1625 AND 2025
NOTE: Read the entire instruction manual before starting the
install.
This symbol indicates a change since the last issue.
TABLE OF CONTENTS
Page
INTRODUCTION 1..................................
HOW IT WORKS 1..................................
SAFETY CONSIDERATIONS 1........................
APPLICATION CONSIDERATIONS 2..................
INSTALLATION 3--5.................................
START--UP AND OPERATION 6.......................
MAINTENANCE 6..................................
TROUBLESHOOTING 7..............................
SPECIFICATIONS AND DIMENSIONS 8................
WARRANTY 9......................................
INTRODUCTION
Congratulations for selecting the Perfect Airt Purifier for your
home comfort system! The Perfect Airt Purifier is proven to
remove and kill airborne germs and allergens, including viruses,
bacteria, and mold spores. The Perfect Airt Purifier is a
cornerstone of Bryant’s Perfect AirtSolutions for providing
healthier, cleaner air in your home.
HOW IT WORKS
The Perfect Airt Purifier provides extremely high filtration
performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The Perfect Airt Purifier
treats the entire air--stream through a state of the art, three--stage
process, exclusive to Bryant.
In stage one, the particles are electrically charged by a
precision--point ionization array a s they enter the Perfect Airt
Purifier.
In stage two, the charged particles are electrically attracted to
the air purification cartridge, which is located within an electric
field.
In stage three, captured particles are killed by electrical current
flow and ion bombardment.
A06054
Fig. 1 -- GAPA Unit
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock
or other c onditions which may cause personal injury or property
damage. Consult a qualified installer, service a gency, or your
distributor or branch for information or assistance. The
qualified installer or agency must use factory authorized kits or
accessories when modifying this product. Refer to the
individual instructions packaged with the kits or accessories
when installing.
Follow all safety codes. Wear safety glasses and work gloves.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warning or cautions attached to the
unit. Consult local building codes a nd National Electrical Code
(NEC) for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol
. When you see this symbol on the unit
and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words DANGER,
WARNING, and CAUTION. These words are used with the
safety--alert symbol. DANGER identifies the most serious
hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal
injury or death. CAUTION is used t o identify unsafe practices
which may result in personal injury or product and property
damage. NOTE is used to highlight suggestions which will
result in enhanced installation, reliability, or operation.
Page view 0
1 2 3 4 5 6 7 8 9 10

Summary of Contents

Page 1 - Operating Instructions

1Installation, Start--Up, andOperating InstructionsGAPAPERFECT AIRT PURIFIERSIZES 1625 AND 2025NOTE: Read the entire instruction manual before startin

Page 2 - APPLICATION CONSIDERATIONS

10Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.EB

Page 3 - INSTALLATION

2APPLICATION CONSIDERATIONSThe Perfect Airt Purifier is designed for use in the return airduct of a forced air heating, cooling, and ventilation syste

Page 4 - Side Mount

3INSTALLATIONStep 6—Check Perfect Airt Purifier ComponentsCUT HAZARDFailure to follow this caution may result in personal injury.Sheet metal parts may

Page 5 - Adapters

4Step 8—Mount the CabinetELECTRICAL SHOCK HAZARDFailure to follow this warning could result in personal injuryor death.Before installing or servicing

Page 6 - MAINTENANCE

5FurnaceAirflowAirflowAdaptersA05274Fig. 5 -- Use of Furnace Adapters Note (optional): Slip returnduct adapters onto flangeson air return duct s

Page 7 - Door Switch Magnet

6Sample Furnace Circuit BoardPower Cordto EAC TerminalsAlternate Power Cord Pass-Thru HoleUse cable connector to securepower cord to cabinetPower Supp

Page 8 - GAPAGAPA

7Step 1—Turn the heating and cooling system off.ELECTRICAL SHOCK HAZARDFailure to follow this warning could result in personalinjury or death.Before i

Page 9 - LIMITED WARRANTY

8Specifications and DimensionsSpecifications GAPAAXBB1625 GAPAAXBB2025Color Taupe Metallic Taupe MetallicCabinet Material 20 Ga. Powder Coated Steel 2

Page 10 - --- 0 --- 2

9 Bryant Heating & Cooling Systems FOR SERVICE OR REPAIR, FOLLOW THESE STEPS IN ORDER: FIRST: Contact the installer. You may find

Related models: GAPAAXBB2025