Table 1 Outputs
EQUIPMENT
CONFIGURATION
OPTION #1
THERMOSTAT
FACTORY
CONFIGURATION
COOL
STAGE 1
HEAT
STAGE 1
HEAT
STAGE 2
EM HEAT
AC, PC AC, HP Y, G W --- --- --- ---
HP, PH
RVS = C
HP Y, G , O / B Y, G Y, G , W W
HP, PH
RVS = H
HP Y, G Y, G , O / B Y, G , W, O / B W
WIRING DIAGRAMS
A06566
Fig. 1 -- A/C Thermostat Typical Installation
A06567
Fig. 2 -- HP Thermostat Typical Installation