SPECIFICATIONS
UNIT SIZE-SERIES 024-A 030-A 036-A 042-A
Operating Weight (Lb) 291 291 291 291
ELECTRICAL
Unit Volts—Hertz—Phase 208/230—60—1
Operating Voltage Range* 187–253
Compressor— Rated Load Amps 13.5 14.7 15.4 18.6
Locked Rotor Amps 61.0 72.5 83.0 105.0
Condenser Fan Motor—Full Load Amps 0.75 0.75 1.10 1.10
Minimum Unit Ampacity for Wire Sizing TBD TBD TBD TBD
Minimum Wire Size (60°C Copper) (AWG)† TBD TBD TBD TBD
Minimum Wire Size (75°C Copper) (AWG)† TBD TBD TBD TBD
Maximum Wire Length (60°C) (Ft)‡ TBD TBD TBD TBD
Maximum Wire Length (75°C) (Ft)‡ TBD TBD TBD TBD
Maximum Branch Circuit Fuse Size** TBD TBD TBD TBD
COMPRESSOR AND REFRIGERANT
Compressor— Manufacturer Copeland
Type Scroll
Refrigerant— Type R-410A
Amount (Lb)†† 9.88 10.25 10.25 10.50
OUTDOOR COIL & FAN
Coil Face Area (Sq Ft) 18.25 18.25 18.25 18.25
Fins per In.—Rows—Circuits 20—2—4 20—2—4 20—2—4 20—2—4
Fan Motor HP and RPM 1/8 and 825 1/8 and 825 1/5 and 825 1/5 and 825
Rated Airflow (CFM) 2400 2400 2800 2800
OPTIONAL EQUIPMENT
Support Feet—4 In. (4) KSASF0101AAA
Coastal Filter KAACF0201MED
Time-Delay Relay KAATD0101TDR
Cycle Protector—5-Minute Time Delay KSACY0101AAA
Start Assist—Capacitor/Relay Type KSAHS1501AAA
TXV (Hard Shutoff) KSATX0201HSZ KSATX0301HSZ
Filter Drier (Suction Line) KH45LG140 (RCD) KH45LG141 (RCD)
Evaporator Freeze Thermostat‡‡ KAAFT0101AAA
Liquid-Line Solenoid Valve (LSV) KAALS0201LLS
Winter Start Control KAAWS0101AAA
Low-Ambient Pressure Switch KSALA0301410
Low-Ambient Controller P251-0083 (RCD)
MotorMaster® Control*** 32LT660004 (RCD)
Ball Bearing Fan Motor HC38GE230
Thermostat—Auto Changeover, Non-Programmable,
°F/°C, 1-Stage Heat, 1-Stage Cool
TSTATBHNAC01-A
Thermostat—Auto Changeover, 7-Day Programmable,
°F/°C, 1-Stage Heat, 1-Stage Cool
TSTATBHPAC01-A
Thermidistat™ Control—Programmable Thermostat
with Humidity Control
TSTATBHPRH01-A
Thermostat—Manual Changeover, Non-Programmable,
°F, 1-Stage Heat, 1-Stage Cool
HH07AT212
Outdoor Air Temperature Sensor TSTATXXSEN01
Backplate for Non-Programmable Thermostat TSTATXXNBP01
Backplate for Programmable Thermostat TSTATXXPBP01
Thermostat Conversion Kit (4 to 5 Wire)—10 Pack TSTATXXCNV10
* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.
If other than uncoated (non-plated), 60° or 75°C (140° or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used,
consult applicable tables of the NEC (ANSI/NFPA 70).
If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name
ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-30.
Length shown is as measured 1 way along the wire path between the unit and the service panel for a voltage drop not to exceed 2 percent.
** Time-delay fuse or circuit breaker.
†† The factory refrigerant charge is for 15 ft of interconnecting tubing. For tubing lengths other 15 ft, refer to the Long-Line Application Guideline and Service Manual for
Residential Split-System Air Conditioners and Heat Pumps using R-410A.
‡‡ Use with low-ambient pressure switch.
*** Fan motor with ball bearings required.
TBD—To Be Determined
NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.