Form No. PDS 533A.24.1 AIR CONDITIONERwith Puron ® 533A (60 Hz) Sizes 024 thru 060 Model 533A Energy-Efficient Air Conditioners incorporateinnovati
—10— COMBINATION RATINGS Continued See notes on page 13. UNITSIZE-SERIESINDOORMODELTOT.CAP.BTUH FACTORY-SUPPLIED ENHANCE-MENTSEEREERStandardRatingBry
—11— COMBINATION RATINGS Continued See notes on page 13. UNITSIZE-SERIESINDOORMODELTOT.CAP.BTUH FACTORY-SUPPLIED ENHANCE-MENTSEEREERStandard RatingBr
—12—COMBINATION RATINGS ContinuedSee notes on page 13.UNITSIZE-SERIESINDOORMODELTOT.CAP.BTUH FACTORY-SUPPLIED ENHANCE-MENTSEEREERStandardRatingBryant
—13—* Tested combination.† In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degrada
—14—DETAILED COOLING CAPACITIES*See notes on page 19.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†TotalSysKw*
—15—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 19.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T
—16—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 19.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T
—17—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 19.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T
—18—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 19.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T
—19—DETAILED COOLING CAPACITIES* Continued* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 21
—2— DIMENSIONS A SQAIR INAIR IN3/8-IN. DIATIEDOWNKNOCKOUTS(2) PLACESHGFELKJAIR INMNAIR DISCHARGEAIR INAIR DISCHARGENO
—20—CONDENSER ONLY RATINGS*See notes on page 21.SST°FCONDENSER ENTERING AIR TEMPERATURES °F55 65 75 85 95 105 115 125533AN024-A30TCG 23.3 22.1 20
—21—CONDENSER ONLY RATINGS* Continued* ARI listing applies only to systems shown in Ratings and Performance table.KW — Total Power (Kw)SDT — Saturated
—22—SYSTEM DESIGN SUMMARY1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less t
—23—
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICEUNIT MUST BE INSTALLED IN ACCORDANCEWITH INSTALLATION INSTRUCTIONSCancels: NEW© 2000 Bryant Heating &a
—3— RECOMMENDED TUBE DIAMETERS * For tube sets greater than 50 ft, consult Residential Split System Application Guideline and Service Manual. CHECK-F
—4— SPECIFICATIONS See notes on page 6. UNIT SIZE-SERIES 024-A 030-A/A 036-A/A Operating Weight (Lb) 143 138 156 ELECTRICAL Unit Volts—Hertz—Phase 20
—5— SPECIFICATIONS Continued UNIT SIZE-SERIES 042-A/A 048-A/A 060-A/A Operating Weight (Lb) 197 203 238 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—
—6— ACCESSORY USAGE GUIDELINE * For tubing line sets greater than 50 ft, refer to Residential Split-System Long-Line Application Guideline and Servic
—7— ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued 9. Liquid-Line Solenoid Valve (LSV) An electrically operated shutoff valve to b
—8— COMBINATION RATINGS See notes on page 13. UNITSIZE-SERIESINDOORMODELTOT.CAP.BTUH FACTORY-SUPPLIED ENHANCE-MENTSEEREERStandardRatingBryant Gas Fur
—9— COMBINATION RATINGS Continued See notes on page 13. UNITSIZE-SERIESINDOORMODELTOT.CAP.BTUH FACTORY-SUPPLIED ENHANCE-MENTSEEREERStandardRatingBrya