Controls and accessories part no. nomenclature
ACCESSORIES
K V B CN 01 01 BAU
CONTROL DESCRIPTION
BAU — Bryant Automatic Control
BBS — Bryant Basic Control
BST — Bryant Standard Control
ACCESSORY DESCRIPTION
6FM — 6 in. Flowmeters (2)
7FM — 7 in. Flowmeters (2)
8FM — 8 in. Flowmeters (2)
EXH — Exhaust Hood
HOD — Intake Hood
KIT — Balancing Kit
VIR — Interlock Relay
TIMER DESCRIPTION
20C 20-Minute Timer Kit Carrier
60M — 60 Minute Adjustable Timer Kit
FILTER DESCRIPTION
112 — 11-1/2 x 12-3/4
116 — 11-7/8 x 16-5/8
123 — 12-15/16 x 13-1/2
145 — 14-3/8 x 15-1/2
713 — 7-13/16 x 13-1/2
810 — 8-1/8 x 10-3/4
812 — 8-7/8 x 12-3/4
916 — 9 x 16-5/8
01 — Single Pack
01 — Part Number
AC — Accessory
CN — Control
FL — Filter Media
TM — Timer
A — Original Series
B — Second Series
V — Heat Recovery Ventilator (HRV)
K — Accessory Kit
Kit Number Description Where Used
KVBCN0101CBS
Basic HRV Control Used with all HRVs
KVBCN0101CST
Standard HRV Control Used with all HRVs
KVBCN0101CAU
Automatic HRV Control HRVBLSVU, HRVBBLVU
KVAAC0101VIR
Interlock Relay When combining an HRV with a Furnace or Fan Coil
KVATM010120C
20 Minute Push Button Timer Used with all HRVs when 20 minute manual operation is required
KVATM010160M
60 Minute Timer Used with all HRVs, time is adjustable between 10 and 60 minutes
KVAAC0101HOD
Exterior Intake and Exhaust Hood 2 Required
KVAAC0101KIT
Start up Balancing Kit Start up Balancing Kit, includes (2) 6 in. Flow Meter Collars & Magnehelic Gage
KVAAC01016FM
6 in. Flow Meter Collar At start up, when 6 in. duct work is connected to HRV
KVAAC01017FM
7 in. Flow Meter Collar At start up, when 7 in. duct work is connected to HRV
KVAAC01018FM
8 in. Flow Meter Collar At start up, when 8 in. duct work is connected to HRV
KVAFK0101150
Internal Filter Used with HRVBBLHU 1150 Unit 11 3/4 x 12 7/8 x 3/4 (2)
KVAFK0201200
Internal Filter Used with HRVBBLHU 1250 Unit 11 3/4 x 16 3/4 x 3/4 (2)
KVAFL0101713
Internal Filter Used with HRVBBSVU 1150 Unit 7 13/16 x 13 1/2 (2)
KVAFL0101123
Internal Filter Used with HRVBBSVU 1200 Unit 12 15/16 x 13 1/2 (2)
KVAFL0101123
Internal Filter Used with HRVBBLVU 1200 Unit 12 15/16 x 13 1/2 (2)
KVAFL0101145
Internal Filter Used with HRVBBLVU 1200 Unit 14 3/8 x 15 1/2
KVAFL0101810
Internal Filter Used with HRVBBLVU 1330 Unit 8 1/8 x 10 3/4 (1)
KVAFL0101145
Internal Filter Used with HRVBBLVU 1330 Unit 14 3/8 x 15 1/2 (1)
KVAFL0101810
Internal Filter Used with HRVBBLVU 1200 Unit 8 1/8 x 10 3/4 (1)