Fig. 14—Unit Wiring Diagram
A97508
LEGEND
ALS1 AUXILIARY LIMIT SWITCH, OVERTEMP. MANUAL RESET, SPST (N.C.)
ALS2 AUXILIARY LIMIT SWITCH, OVERTEMP. AUTO RESET, SPST (N.C.)
BHI / LOR BLOWER MOTOR SPEED CHANGE RELAY, SPDT
BHT / CLR BLOWER MOTOR SPEED CHANGE RELAY, SPDT
BLWM BLOWER MOTOR, 4 or 5 -SPEED, PERMANENT-SPLIT-CAPACITOR
BLWR BLOWER MOTOR RELAY, SPST (N.O.)
CAP CAPACITOR
CPU MICROPROCESSOR AND CIRCUITRY
DSS DRAFT SAFEGUARD SWITCH (N.C.)
EAC-1 ELECTRONIC AIR CLEANER CONNECTION (115 VAC, 1 AMP MAX.)
EAC-2 ELECTRONIC AIR CLEANER CONNECTION (COMMON)
FRS1 FLAME ROLLOUT SWITCH OVERTEMP. MANUAL RESET, SPST (N.C.)
FRS2 FLAME ROLLOUT SWITCH OVERTEMP. MANUAL RESET, SPST (N.C.)
FSE FLAME-PROVING SENSOR ELECTRODE
FU1 FUSE, 3 AMP, AUTOMOTIVE BLADE TYPE, FACTORY INSTALLED
FU2 FUSE, FIELD INSTALLED
GV GAS VALVE, REDUNDANT LOW-HEAT OPERATORS, 2-STAGE
HPS HIGH-HEAT PRESSURE SWITCH, SPST (N.O.)
HPSR HIGH-HEAT PRESSURE SWITCH RELAY, SPST (N.C.)
HSI HOT-SURFACE IGNITER (115 VAC)
HSIR HOT-SURFACE IGNITOR RELAY, SPST (N.O.)
HUM 24VAC HUMIDIFIER CONNECTION (0.5 AMP. MAX.)
IDM INDUCED DRAFT MOTOR, 2-SPEED, SHADED-POLE
IDR INDUCER MOTOR RELAY, SPST (N.O.)
IHI / LOR INDUCER MOTOR SPEED CHANGE RELAY, SPDT
ILK BLOWER DOOR INTERLOCK SWITCH, SPST (N.O.)
JB JUNCTION BOX
LED LIGHT-EMITTING DIODE FOR STATUS CODES
LGPS LOW GAS-PRESSURE SWITCH, SPST (N.O.)
LPS LOW-HEAT PRESSURE SWITCH, SPST (N.O.)
LS LIMIT SWITCH, OVERTEMPERATURE-AUTO RESET, SPST (N.C.)
MGVR MAIN GAS VALVE RELAY, DPST (N.O.)
-
1 = VALVE
-
2 = HUMIDIFIER
PL1 12-CIRCUIT CONNECTOR
PL2 9-CIRCUIT CONNECTOR
PL3 3-CIRCUIT IDM CONNECTOR
PL6 2-CIRCUIT HSI CONNECTOR
SW1 HIGH-HEAT-ONLY SWITCH, SPST (MANUAL)
*
SW2 LOW-HAT-ONLY SWITCH, SPST (MANUAL)
*
SW3 & 4 BLOWER-OFF DELAY SETTING SWITCHES,
SPST (MANUAL)
*
TJ TWINNING JUMPER, SPDT FOR MASTER OR
SLAVE STATUS (MANUAL CHANGE OVER)
TRAN TRANSFORMER-115VAC/24VAC
TWIN/TEST 1-CIRCUIT TWINNING BUSS CONNECTOR,
ALSO STATUS CODE RECALL
JUNCTION
TERMINAL
CONTROL TERMINAL
FACTORY POWER WIRING (115VAC)
FACTORY CONTROL WIRING (24VAC)
FIELD POWER WIRING (115VAC)
FIELD CONTROL WIRING (24VAC)
CONDUCTOR ON CONTROL
FIELD WIRING SCREW TERMINAL
FIELD GROUND
EQUIPMENT GROUND
FIELD SPLICE
PLUG RECEPTACLE
NOTES:
324459-101 REV. A
1. Use only copper wire between the disconnect switch and the unit.
2. If any of the original wire, as supplied, must be replaced, use the
same or equivalent type wire.
3. Inducer (IDM) and blower (BLWM) motors contain internal auto-reset
thermal overload switches.
4. Blower motor speed selections are for average conditions. See
Installation Instructions for details on optimum speed selection.
5. Replace only with a 3-AMP fuse.
6. Auxiliary limit switches (ALS1 & 2) used on some horizontal and
some downflow models.
7. This wire must be connected to furnace sheet metal for
control to prove flame.
8. Factory connected when LGPS not used.
RED
LS
FRS2
RED
RED
FRS1
(WHEN USED)
ALS1
DSS
ORN
LGPS
YEL
NOTE #8
LPS
NOTE #8
(WHEN USED)
RED
YEL
ORN
(WHEN USED)
NOTE #6
ALS2
ORN
SWITCH
12
HEAT
SET-UP
SWITCH
NORM
HI HT
LO HT
*
ON
OFF
OFF
ON
BLOWER-
OFF DELAY
(SEC.)
SWITCH
3
4
90 SEC
135 SEC
*
180 SEC
225 SEC
ON
OFF
OFF
ON
2-STAGE
FURNACE
CONTROL
FACTORY
SETTINGS
1
2
34
ON
OFF
3
2
1
BLU
BLOWER-OFF DELAY
BLOWER-OFF DELAY
LOW-HEAT ONLY
HIGH-HEAT ONLY
*
RED
RED
ORN
W2 Com
24V
W/W1 Y/Y2 R G HUM
LED
S
M
TJ
TWIN
TEST
12
11 10
GRN
GRY
BRN
P1
WHT
BLK
GRY
YEL
321
9
87
WHT
FSE
BLK
GRY
BRN
HPS
BRN
HI
P
BLU
GRN
M
IDM
HSI
GRN
ILK
JB
L1
WHTPL6
RED
BLK
WHT
BLK
WHT
12
123
PL3
WHT
BLK
RED
PL2
PR1 PR2
L1 L2
COMMON
HI-COOL
HI-GAS
HEAT
EAC-2
EAC-1
LO-GAS
HEAT
SPARE
SEC1
FU1
SEC2
NOTE #4
BLWM
BRN
BRN
CAP
WHT
BLK
TRAN
RED
BLU
WHT
BLK
GV
C
GRN
FUSED DISCONNECT
SWITCH (WHEN REQ’D)
NOTE #1
BLK
WHT
GRN
L2
GRN
FU2
CONNECTION DIAGRAM
L1
BLWR
TO 115VAC FIELD DISCONNECT SWITCH
NOTE #1
EQUIPMENT GROUND
LO-GAS-HEAT
HI-GAS-HEAT
SPARE
NOTE #4
COMMON
HSIR
EAC-1
SCHEMATIC DIAGRAM (NATURAL GAS & PROPANE)
EAC-2
3
1
HSI
2
9
PL2
PR2
115VAC
PR1
TRAN
24VAC
IDR
L2
ILK
IDM
BLWM
BHI / LOR
BHT / CLR
CAP
BRN
BRN
PL6
IHI / LOR
SEC1
FU1
NOTE #5
1
2
3
HI
COM
HPSR
1
5
6
2
N/A
N/A
HI-COOL
PL3
4
7
SEC2
8
LS
ALS1
DSS
ALS2
FRS1
(WHEN USED)
FRS2
N/A
12
2
3
MGVR-2
9
6
NOTE #8 LPS
(WHEN USED)
TWIN
TEST
SLAVE
MASTER
W/W1
R
HUM
TWINNING
JUMPER
TJ
W2
Y/Y2
G
MGVR-1
NOTE #8
HPS
5
4
1
10
7
8
N/A
N/A
FSE
11
HI
M
P
C
NOTE#7
PL1
COMPONENT TEST
To initiate the component test sequence with no thermostat inputs and with all inducer Post-Purge and Blower-Off Delay periods completed, short the "TWIN/TEST" terminal to the "
COM" terminal for about two seconds. The control will
turn ON the inducer motor Low-Speed, inducer motor High-Speed, HSI, blower motor Low-Gas-Heat Speed, blower motor High-Gas-Heat Speed, and blower motor High-Cool Speed for 7-15 seconds each. Neither the gas valve nor the humidifier will be
turned ON.
CPU
LGPS
LO
SW1
GV
ORN
SW4
SW3
SW2
C
OM
9. Symbols are an electrical representation only.
10. BLOWER-ON DELAY: Gas heating 45 seconds,
Cooling/Heat Pump 2 seconds.
11. Cooling/Heat Pump BLOWER-OFF DELAY is 90
seconds.
12. IGNITION-LOCKOUT will occur after four consecutive
unsuccessful trials-for-ignition. Control will automatically
reset after three hours.
13. Control must be grounded at pin 10 of 12-pin connector.
14. NA - Not Applicable
15. Spare terminal and wire not available on some
applications. Insulate connector if not available.
RED
LO
RED
MED LO
BLU
COM WHT
BLK
HI
YELMED HI
MED
COM
HI
MED
MED LO
LO
NOTE #15
ORN
SPARE
MED HI
SPARE
BLU
NOTE #15
—11—