Bryant EVOLUTION 577D----A User Manual

Browse online or download User Manual for Split-system air conditioners Bryant EVOLUTION 577D----A. 577D - County Heating & Air Conditioning Inc

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
Product Data
577D----A
EVOLUTIONr 15 SEER SINGLE--PACKAGED AIR CONDITIONER AND
GAS FURNACE SYSTEM W/PURONR (R--410A) REFRIGERANT
2--5 NOMINAL TONS (SIZES 24--60)
A09032
Fig. 1 -- Unit 577D--A
Single--Packaged Products with Energy--Saving Features and
Puron
®
refrigerant.
S Direct Spark Ignition
S Up to 15.5 SEER
S Up to 12.0 EER
S Meets Energy Star requirements
S Up to 80.1% AFUE
S Low Sound Levels
S Full Featured ECM Motor (Standard)
S Factory Installed TXV
S Stainless Steel Heat Exchanger
S Two Stage Cooling and Heating
S Advanced Dehumidification Feature
FEATURES/BENEFITS
One--piece heating and cooling units with low sound levels, easy
installation, low maintenance, and dependable performance.
Puron
®
Environmentally--Sound Refrigerant is Bryants unique
refrigerant designed to help protect the environment. Puron
refrigerant is an HFC refrigerant which does not contain chlorine
that can harm the ozone layer. Puron refrigerant is in service in
millions of systems proving highly reliable, environmentally sound
performance.
Perfect Humidityt Technology featuring Evolutionr control
and Variable--Speed Blower motor and two--stages of cooling
and heating provide greater comfort, humidity control, and energy
efficiency.
Innovative Unit Base Design
On the inside a high--tech composite material will not rust and
incorporates a sloped drain pan which improves drainage and helps
inhibit mold, algae and bacterial growth. On the outside metal base
rails provide added stability as well as easier handling and rigging.
Variable--Speed Blower motors provide better comfort and
energy efficiency. Economical constant fan for less than $50 a year,
which provides improved indoor air quality and more even
temperatures from room to room; and reduced indoor noise due to
lower air velocity. In addition, you’ll realize improved installation
flexibility with 3 different airflow choices for best overall comfort.
Easy installation
Factory--assembled package is a compact, fully self--contained,
combination gas heating/electric cooling unit that is pre--wired,
pre--piped, and pre--charged for minimum installation expense.
These units are available in a variety of standard and optional
heating/cooling size combinations. Units are lightweight and install
easily on a rooftop or at ground level. The high tech composite unit
base eliminates rust problems associated with ground level
applications.
Convertible duct configuration
Unit is designed for use in either downflow or horizontal
applications. Each unit can be converted from horizontal to
downflow and includes horizontal duct covers. Downflow
operation is provided in the field to allow vertical ductwork
connections. The basepan seals on the bottom openings to ensure a
positive seal in the vertical airflow mode.
Efficient operation
High--efficiency design with SEERs (Seasonal Energy Efficiency
Ratio) of up to 15.5 and AFUE (Annual Fuel Utilization
Efficiency) ratings as high at 80.1%.
Energy--saving, direct spark ignition saves gas by operating only
when the room thermostat calls for heating. Standard units are
furnished with natural gas controls. A low--cost field installed kit
for propane conversion is available for all units.
Dedicated Low NOx units designed for California installations.
These models meet the California maximum oxides of nitrogen
(NOx) emissions requirement of 40 nanograms/joule or less as
shipped from the factory and MUST be installed in California Air
Quality Management Districts or any other location where a Low
NOx rule exists.
Durable, dependable components
Compressors have two stages of cooling and are designed for high
efficiency. Each compressor is hermetically sealed against
contamination to help promote longer life and dependable
operation. Vibration isolation provides quiet operation.
Compressors have internal high--pressure and overcurrent
protection.
Monoport inshot burners produce precise air--to--gas mixture,
which provides for clean and efficient combustion. The large
monoport on the inshot (or injection type) burners seldom, if ever,
requires cleaning. All gas furnace components are accessible in one
compartment.
Turbo--tubulart heat exchangers are constructed of 409
stainless steel for corrosion resistance and optimum heat transfer
for improved efficiency. The tubular design permits hot gases to
make multiple passes across the path of the supply air.
In addition, dimples located on the heat exchanger walls force the
hot gases to stay in close contact with the walls, improving heat
transfer.
ECM Motor is standard on all 577D----A models.
Page view 0
1 2 3 4 5 6 ... 29 30

Summary of Contents

Page 1 - Product Data

1Product Data577D----AEVOLUTIONr 15 SEER SINGLE--PACKAGED AIR CONDITIONER ANDGAS FURNACE SYSTEM W/PURONR (R--410A) REFRIGERANT2--5 NOMINAL TONS (SIZES

Page 2 - TABLE OF CONTENTS

10ACCESSORY DIMENSIONSRETURN AIR SMALLBASE UNITSUPPLYAIRLARGEBASE UNITUNIT PLACEMENT ON COMMON CURBLARGE CURBSMALL OR LARGE BASE UNITSMALL/COMMON CURB

Page 3 - MODEL NUMBER NOMENCLATURE

11SELECTION PROCEDUREDetermine cooling and heating requirements at designconditions:Given:REQUIRED COOLING CAPACITY (TC) 34,500 BTUH...SENSIBLE HEA

Page 4 - AHRI* CAPACITIES

12PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table577D----A24 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _

Page 5 - PHYSICAL DATA

13PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table577D----A30 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _

Page 6 - PHYSICAL DATA (CONT)

14PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table577D----A36 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _

Page 7 - MANUAL OUTSIDE AIR DAMPER

15PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table577D----A42 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _

Page 8

16PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table577D----A48 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _

Page 9

17PERFORMANCE DATA--STANDARD ECM INDOOR MOTORCooling Extended Performance Table577D----A60 High CoolEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES _

Page 10 - ACCESSORY DIMENSIONS

18PERFORMANCE DATA (CONT)LEGENDBF— B y pass Factoredb— Entering Dry---BulbEwb — Entering Wet--- BulbkW — Total Unit Power Inputldb— Leaving Dry---Bulb

Page 11 - SELECTION PROCEDURE

19PERFORMANCE DATA (CONT)High Altitude Compensation: Natural GasNameplateInput, HighStage(Btu/hr)Rated Heating Input (Btu/hr), Natural Gas at Installa

Page 12 - 577D-- -- A

2Direct--drive, PSC (Permanent Split Capacitor) condenser fanmotors are designed to help reduce energy consumption andprovide for cooling operation do

Page 13

20PERFORMANCE DATA (CONT)Wet/Dry Coil Air Delivery (CFM)-- Low Stage208/230 VOLTUNITSIZESYSTEM SETTINGEXTERNAL STATIC PRESSURE (IN. W.C.)0.1 0.2 0.3 0

Page 14

21TYPICAL PIPING AND WIRINGROOFRETURN-AIRFLEXIBLE DUCTCEILINGCONCENTRIC DIFFUSER BOX(FIELD-SUPPLIED)SUPPLY-AIRFLEXIBLE DUCTROOF-MOUNTINGCURBA09226A092

Page 15

22APPLICATION DATACondensate trap — A 2--in. (51 mm) condensate trap must be fieldsupplied.Ductwork— Securedownflow dischargeductwork toroofcurb.Forho

Page 16

23CONNECTION WIRING SCHEMATIC—208/230--1--60 GAS INPUTS 040, 060, 090 kBtu/hrA10217C577D-- -- A

Page 17

24LADDER WIRING SCHEMATIC—208/230--1--60 GAS INPUTS 040, 060, 090 kBtu/hrA10217L577D-- -- A

Page 18 - PERFORMANCE DATA (CONT)

25CONNECTION WIRING SCHEMATIC—208/230--1--60 GAS INPUTS 115, 130 kBtu/hrA10219C577D-- -- A

Page 19

26LADDER WIRING SCHEMATIC—208/230--1--60 GAS INPUTS 115, 130 kBtu/hrA10219L577D-- -- A

Page 20

27CONTROLSSequence of OperationCooling Operation—With a call for first stage cooling, the outdoorfan and low--stage compressor are energized. If low--

Page 21 - TYPICAL PIPING AND WIRING

28GUIDE SPECIFICATIONSSINGLE--PACKAGED AIR CONDITIONER AND GASFURNACE SYSTEM CONSTANT VOLUMEAPPLICATIONHVAC GUIDE SPECIFICATIONSSIZE RANGE: 2 TO 5 TON

Page 22 - ELECTRICAL DATA

29GUIDE SPECIFICATIONS (CONT)M. Low NOx (Natural Gas only) Option:Shall provide NOx reduction to values below 40 nanograms/joule to meet California’s

Page 23

3MODEL NUMBER NOMENCLATURE577D --- ---24AType of U nit577D --- Single PackagedAir Conditioner andGas Furnace SystemNominal Cooling Capacity24 --- 2.0

Page 24

30Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.E2

Page 25

4AHRI* CAPACITIESCooling Capacities, EfficienciesUnit 577D----A Nominal TonsStandard CFM(High / Low Stage)Net CoolingCapacities (Btuh)(High / Low Stag

Page 26

5PHYSICAL DATAUNIT SIZE 24040 24060 30040 30060 36060 36090 42060 42090NOMINAL COOLING CAPACITY (ton) 2 2 2 --- 1 / 2 2 --- 1 / 2 3 3 3 --- 1 / 2 3 --

Page 27 - CONTROLS

6PHYSICAL DATA (CONT)UNIT SIZE 48090 48115 48130 60090 60115 60130NOMINAL COOLING CAPACITY (ton) 4 4 4 5 5 5NOMINAL HEATING INPUT (Btu/hr) 90,000 115,

Page 28 - GUIDE SPECIFICATIONS

7OPTIONS AND ACCESSORIESITEM DESCRIPTIONFACTORYINSTALLEDOPTIONFIELDINSTALLEDACCESSORYCoil Options Base unit with tin plated indoor coil hairpins XCorp

Page 29 - GUIDE SPECIFICATIONS (CONT)

8577D----A24--30 UNIT DIMENSIONSA09556577D-- -- A

Page 30

9577D----A36--60 UNIT DIMENSIONSA09557577D-- -- A

Comments to this Manuals

No comments