Bryant 582A User Manual

Browse online or download User Manual for Water heaters & boilers Bryant 582A. Model 582A Sizes 018-060

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SINGLE-PACKAGED
GAS HEATING/ELECTRIC
COOLING UNITS
Model 582A
Sizes 018-060
1-1/2 to 5 Nominal Tons
Form No. PDS 582A.18.4
Single-Packaged Rooftop Units with
Direct Spark Ignition
Low Sound Levels
Up to 81% AFUE
10 SEER
FEATURES/BENEFITS
One-piece heating and cooling units with low sound levels, easy
installation, low maintenance, and dependable performance.
EASY INSTALLATION
—Factory-assembled package is a com-
pact, fully self-contained, combination gas heating/electric cool-
ing unit that is pre-wired, pre-piped, and pre-charged for
minimum installation expense.
The 582A units are available in a variety of standard and optional
heating/cooling size combinations with voltage options to meet
residential and light commercial requirements. Units are light-
weight and install easily on a rooftop or at ground level. The high
tech composite unit base eliminates rust problems associated
with ground level applications.
CONVERTIBLE DUCT CONFIGURATION
—Unit is designed
for easy use in either downflow or horizontal applications. Each
unit is easily converted from horizontal to downflow with the use
of two included duct covers.
EFFICIENT OPERATION
High-Efficiency Design
offers SEER (Seasonal Energy Effi-
ciency Ratios) of 10.0 and AFUE (Annual Fuel Utilization Effi-
ciency) ratings as high as 81.1%.
Energy-Saving, Direct Spark Ignition
saves gas by operating
only when the room thermostat calls for heating. Standard units
are furnished with natural gas controls. A low-cost field-installed
kit for propane conversion is available for all units.
582A units with an “N”
in the thirteenth position of model num-
ber are dedicated Low NOx units designed for California instal-
lations. These models meet the California maximum oxides of
nitrogen (NOx) emissions requirement of 40 nanograms/joule or
less as shipped from the factory and
MUST
be installed in Cali-
fornia Air Quality Management Districts where a Low NOx rule
exists.
DURABLE, DEPENDABLE COMPONENTS
Compressors
are designed for high efficiency. Each compres-
sor is hermetically sealed against contamination to help promote
longer life and dependable operation. Each compressor also has
vibration isolation to provide quieter operation. All compressors
have internal high pressure and overcurrent protection.
Monoport Inshot Burners
produce precise air-to-gas mixture,
which provides for clean and efficient combustion. The large
monoport on the inshot (or injection type) burners seldom, if
ever, requires cleaning. All gas furnace components are acces-
sible in one compartment.
Turbo-Tubular™ Heat Exchangers
are constructed of alumi-
nized steel for corrosion resistance and optimum heat transfer
for improved efficiency. The tubular design permits hot gases to
make multiple passes across the path of the supply air.
In addition, dimples located on the heat exchanger walls force
the hot gases to stay in close contact with the walls, improving
heat transfer.
Direct-Drive Multi-Speed, PSC (Permanent Split Capacitor)
Blower Motor
is standard on all 582A models.
Direct-Drive, PSC Condenser-Fan Motors
are designed to
help reduce energy consumption and provide for cooling opera-
tion down to 40°F outdoor temperature. Motormaster® II low am-
bient option is available as a field-installed accessory.
Refrigerant System
is designed to provide dependability. Liq-
uid refrigerant strainers are used to promote clean, unrestricted
operation. Each unit leaves the factory with a full refrigerant
charge. Refrigerant service connections make checking operat-
ing pressures easier.
Evaporator and Condenser Coils
are computer-designed for
optimum heat transfer and cooling efficiency. The evaporator
coil is fabricated from copper tube and aluminum fins and is lo-
cated inside the unit for protection against damage. The con-
denser coil is internally mounted on the top tier of the unit.
Copper fin coils and pre-coated fin coils are available from the
factory by special order. These coils are recommended in appli-
cations where aluminum fins are likely to be damaged due to
corrosion and are ideal for seacoast applications.
Low Sound Ratings
ensure a quiet indoor and outdoor environ-
ment with sound ratings as low as 75dB. (See ARI capacity
charts for individual values.)
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Sizes 018-060

SINGLE-PACKAGEDGAS HEATING/ELECTRICCOOLING UNITS Model 582ASizes 018-060 1-1/2 to 5 Nominal TonsForm No. PDS 582A.18.4 Single-Packaged Rooftop Units

Page 2 - FEATURES/BENEFITS (cont)

—10— 582A UNIT CORNER WEIGHTS I DETERMINE COOLING AND HEATING REQUIREMENTSAT DESIGN CONDITIONS: Given:Required Cooling Capacity (TC) ...

Page 3

—11— PERFORMANCE DATANET COOLING CAPACITIES See Legend and Notes on page 13. 582A018TEMP (F)OUTDOORENTERINGAIRINDOOR AIR — CFM/BF525/0.118 600/0.159

Page 4 - PHYSICAL DATA

—12— PERFORMANCE DATA (cont)NET COOLING CAPACITIES See Legend and Notes on page 14. 582A036TEMP (F)OUTDOORENTERINGAIRINDOOR AIR — CFM/BF1050/0.169 12

Page 5 - OPTIONS AND ACCESSORIES

—13— PERFORMANCE DATA (cont)NET COOLING CAPACITIES 582A060TEMP (F)OUTDOORENTERINGAIRINDOOR AIR — CFM/BF1750/0.039 2000/0.053 2250/0.079Indoor Air — E

Page 6 - ECONOMIZER

—14—PERFORMANCE DATA (cont)DRY COIL AIR DELIVERY* — HORIZONTAL AND DOWNFLOW DISCHARGE(Deduct 10% for 208 v)*Air delivery values are without air filter

Page 7

—15—PERFORMANCE DATA (cont)ECONOMIZER/1-IN. FILTER PRESSURE DROPWET COIL PRESSURE DROPFILTER PRESSURE DROP (In. wg)UNIT 582APRESSURE DROP(in. wg)018-0

Page 8

—16—TYPICAL PIPING AND WIRING (Some Units shown with optional Louvered Grille)INDOORTHERMOSTATDISCONNECTPER NEC*FROMPOWERSOURCERETURNAIRTOP COVERFROMG

Page 9 - ACCESSORY DIMENSIONS

—17—APPLICATION DATACONDENSATE TRAP — A 2-in. condensate trap must be fieldsupplied.DUCTWORK — Secure downflow discharge ductwork to roofcurb. For horiz

Page 10 - 582A UNIT CORNER WEIGHTS

—18—TYPICAL WIRING SCHEMATICS 208/230-1-60NOTES:1. If any of the original wires furnished are replaced, they must bereplaced with type 90 degree C wir

Page 11 - NET COOLING CAPACITIES

—19—TYPICAL WIRING SCHEMATIC, 582A; 208/230-3-60COOLING FAN LOGICENERGIZED DE-ENERGIZEDENERGIZED DE-ENERGIZEDHEATING FAN LOGICFIELDSUPPLYPOWER

Page 12 - PERFORMANCE DATA (cont)

—2— MODEL NUMBER NOMENCLATURE 582A N W 024Model No.582A – Single PackagedGas/Electric Unit Electrical SupplyN – 208/230-1-60 P – 208/230-3-60 E –

Page 13

—20—TYPICAL WIRING SCHEMATIC, 582A; 460-3-60COOLING FAN LOGICENERGIZED DE-ENERGIZEDENERGIZED DE-ENERGIZEDHEATING FAN LOGICFIELDSUPPLYPOWERW54

Page 14 - (Deduct 10% for 208 v)

—21—ELECTRICAL DATAUNITSIZE582AV-PH-HzVOLTAGERANGECOMPRESSORCOND FANMOTOREVAP FAN MOTORPOWER SUPPLYMin Max RLA LRA FLA FLA MCAMAX FUSE or BKR018 208/2

Page 15

—22—OPERATING SEQUENCEHeating — When the thermostat calls for heating, terminal “W”is energized, starting the induced draft motor. When the hall-effec

Page 16 - Horizontal Discharge

—23—GUIDE SPECIFICATIONSPackaged Heating/Cooling UnitsConstant Volume ApplicationHVAC Guide SpecificationsSize Range:1-1/2 to 5 Tons, Nominal Cooling4

Page 17 - APPLICATION DATA

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICEUNIT MUST BE INSTALLED IN ACCORDANCEWITH INSTALLATION INSTRUCTIONSForm: PDS 582A.18.4Cancels: PDS 582A.

Page 18 - UNIT COMPONENT ARRANGEMENT

—3— ARI* CAPACITIES COOLING CAPACITIES AND EFFICIENCIES UNIT 582A NOMINAL TONS STANDARD CFMNET COOLING CAPACITIES (Btuh)SEER†SOUND RATINGS** (dB)0180

Page 19

—4— PHYSICAL DATA * Based on altitude of 0 to 2000 feet.† Required filter sizes shown are based on the larger of the ARi (Air Conditioning and Refrige

Page 20

—5— FACTORY-INSTALLED OPTIONSLouvered grille provides hail and vandalism protection. A wire grille is standard on all models. See model number nomen

Page 21 - ELECTRICAL DATA

—6— OPTIONS AND ACCESSORIES (cont) FILTER ACCESS DOOR(HORIZONTALAPPLICATION ONLY.)DO NOT REMOVEFROM DOWNFLOWDISCHARGE.REPLACEMENTPANELHOLE FORECONOM

Page 22 - CONTROLS

—7— BASE UNIT DIMENSIONS — 582A018-042 UNIT ELECTRICAL CHARACTERISTICSUNIT WT. UNIT HEIGHT CENTER OF GRAVITY MM/INLBS. KG. “A” XYZ582A018040 208/230-

Page 23

—8— BASE UNIT DIMENSIONS — 582A048-060 UNIT ELECTRICAL CHARACTERISTICSUNIT WT. UNIT HEIGHT CENTER OF GRAVITY MM/INLBS. KG. “A” XYZ582A048090/115/130

Page 24 - GUIDE SPECIFICATIONS (cont)

—9— Roof Curb DimensionsSide View ROOF CURBUNIT SIZE ODS ORDER NUMBERAIN. [MM]BIN. [MM]CIN. [MM]DIN. [MM] 018-042CPRFCURB006A00 8 [203] 11 [279] 16-1

Comments to this Manuals