Bryant 582A User Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
18
TYPICAL WIRING SCHEMATICS 208/230-1-60
NOTES:
1. If any of the original wires furnished are replaced, they must be
replaced with type 90 degree C wire or its equivalent.
2. See price pages for thermostat and subbases.
3. Use 75 degree C copper conductors for field installation.
4. For high speed IFM, disconnect RED wire from IGC terminal BM
and connect BLK wire from IFM. For medium speed, disconnect
RED wire from IGC terminal BM and connect BLU wire from IFM.
5. Models 4BGX024-036 have LS1 and LS2 wired in series. Models
48GX042-060 have LS1 only.
UNIT COMPONENT ARRANGEMENT
DISCONNECT
PER NEC
GAS SECTION
OUTDOOR FAN
SECTION
COMPRESSOR
SECTION
INDOOR FAN
SECTION
CONTROL BOX
24V
SPLICE BOX
EQUIP
GND
OFM
TRAN
CAP 1
LS1
IFM
CAP3
IGC
CAP 2
HC F
23
21
C
13
11
COMP
C
S
R
IDM
HS
MGV
1 2
1
RS
FS
COOLING FAN LOGIC
ENERGIZED DE-ENERGIZED
ENERGIZED DE-ENERGIZED
HEATING FAN LOGIC
FIELD
SUPPLY
EQUIP_GND
W15 YEL
W14 BLK
PRIMARY
230V
11
21
13
23
C
W16 YEL
W43 BLK
C
BLK
YEL
BRN
CAP 2
C
R
S
W8 BLK
W7 YEL
RED
YEL
BRN/WHT
OR YEL
BRN
V10
YEL
BRN
CAP 1
CAP 3
OFM
COMP
IFM
IDM
(SEE NOTE #4)
GRN-YEL
W24 YEL
W50 V10
QT
QT
W46 BRN
SECONDARY
24V
TRAN1
1
1
230
C
24V
COM
0
G
T
G
0
W
T
W
T+30
T+30
BR
45
BR
RC
RH
B
OFF
HEAT
AUTO
COOL
THI
AHA
WI
OFF
HEAT
AUTO
YI
TCI
COOL
AUTO
FAN
SW
FIELD-THERMOSTAT
ON
G
W13 BLK
24V SPLICE BOX
W19 WHT
W20 GRN
W21 RED
L1
CM
BM
L2L2
L2
J2
IFC
W
G
R
CR
BR
W39 RED
IGC
RS
RS
LS
LS
CS
CS
GV
GV
CR
BR
GVR
FAN
LOGIC
SAFETY
LOGIC
5 AMP
FU
RT
BLU
BLU
V10
V10
GVR
W35 GRA
MGV
W34 BRN
FLAME SEN
YEL
BRN
W41 GRN-YEL
W32 BRN
W46 BRN
GRN-YEL
W32 BRN
W30 BRN
W33 YEL
GROUNDED
TRU STANDOFF
HS
HV
TRAN
FS
C
C
YEL
RS
LS1
1
3
C1
C2
C_
W30 BRN
COMMON
200
W44 RED
1
2
1 2 3
LS2
1
3
V10
SEE NOTE #5
POWER
SCHEMATIC
208/230-1-60
W54 YEL
LS2
CAP 1
LARGE CHASSIS LOC
AHA Adjustable Heat
Anticipator
BR Blower Relay
C Contactor
CAP Capacitor
COMP Compressor Motor
CR Combustion Relay
CS Centrifugal Switch
EQUIP Equipment
FS Flame Sensor
FU Fuse
GND Ground
GV Gas Valve
GVR Gas Valve Relay
HS Hall Effect Sensor
HV High Voltage
TRAN Transformer
I Ignitor
IDM Induced-Draft Motor
IFC Indoor-Fan Contactor
IFM Indoor-Fan Motor
IGC Integrated Gas Unit
Controller
L1 Line
LS Limit Switch
LS1 Limit Switch
MGV Main Gas Valve
NEC National Electrical
Code
OFM Outdoor-Fan Motor
QT Quadruple Terminal
RS Rollout Switch
SEN Sensor
SW Switch
TRAN Transformer
LEGEND
1
3
W6 YEL
H
F
W9 BLU
YEL
W61 YEL
ST
W59 BLU
(582A ONLY)
Field Splice
Terminal (Marked)
Terminal (Unmarked)
Splice
Splice (Marked)
Factory Wiring
Field Control Wiring
Field Power Wiring
Accessory or
Optional Wiring
To Indicate Common
Potential Only, Not
to Represent Wiring
Page view 17