SINGLE-PACKAGE
GAS HEATING/ELECTRIC
COOLING UNITS
Model 582A
Sizes 018-060
1-1/2 to 5 Nominal Tons
Low NOx Models Available
Form No. PDS 582A.18.2
Single-Package Rooftop Units with.
Direct Spark Ignition
Low Sound Levels
AFUE ratings up to 81.1%
10 SEER
AVAILABLE OPTIONS
One-piece heating and cooling units with low sound levels, easy
installation, low maintenance, and dependable performance.
EASY INSTALLATION
—Factory-assembled package is a com-
pact, fully self-contained, combination gas heating/electric cool-
ing unit that is pre-wired, pre-piped, and pre-charged for
minimum installation expense.
The 582A units are available in a variety of standard and optional
heating/cooling size combinations with voltage options to meet
residential and light commercial requirements. Units are light-
weight and install easily on a rooftop or at ground level. The high
tech composite basepan eliminates rust problems associated
with ground level applications.
CONVERTIBLE DUCT CONFIGURATION
—Unit is designed
for easy use in either downflow or horizontal applications. Each
unit is easily converted from horizontal to downflow with addition
of two accessory duct covers.
EFFICIENT OPERATION
High-Efficiency Design
offers SEER (Seasonal Energy Effi-
ciency Ratios) of 10.0 and AFUE (Annual Fuel Utilization Effi-
ciency) ratings as high as 81.1%.
Energy-Saving, Direct Spark Ignition
saves gas by operating
only when the room thermostat calls for heating. Standard units
are furnished with natural gas controls. A low-cost field-installed
kit for propane conversion is available for all units.
582A units with an “N”
in the thirteenth position of model num-
ber are dedicated Low NOx units designed for California instal-
lations. These models meet the California maximum oxides of
nitrogen (NOx) emissions requirement of 40 nanograms/joule or
less as shipped from the factory and
MUST
be installed in Cali-
fornia Air Quality Management Districts where a Low NOx rule
exists.
DURABLE, DEPENDABLE COMPONENTS
Compressors
are designed for high efficiency. Each compres-
sor is hermetically sealed against contamination to help promote
longer life and dependable operation. Each compressor also has
vibration isolation to provide quieter operation. All compressors
have internal high pressure and overcurrent protection.
Monoport Inshot Burners
produce precise air-to-gas mixture,
which provides for clean and efficient combustion. The large
monoport on the inshot (or injection type) burners seldom, if
ever, requires cleaning. All gas furnace components are acces-
sible in one compartment.
Turbo-Tubular™ Heat Exchangers
are constructed of alumi-
nized steel for corrosion resistance and optimum heat transfer
for improved efficiency. The tubular design permits hot gases to
make multiple passes across the path of the supply air.
In addition, dimples located on the heat exchanger walls force
the hot gases to stay in close contact with the walls, improving
heat transfer.
Direct-Drive Multi-Speed, PSC (Permanent Split Capacitor)
Blower Motor
is standard on all 582A models.
Direct-Drive, PSC Condenser-Fan Motors
are designed to
help reduce energy consumption and provide for cooling opera-
tion down to 40°F outdoor temperature. Motormaster® II low am-
bient option is available as a field-installed accessory.
Refrigerant System
is designed to provide dependability. Liq-
uid refrigerant strainers are used to promote clean, unrestricted
operation. Each unit leaves the factory with a full refrigerant
charge. Refrigerant service connections make checking operat-
ing pressures easier.
Evaporator and Condenser Coils
are computer-designed for
optimum heat transfer and cooling efficiency. The evaporator
coil is fabricated from copper tube and aluminum fins and is lo-
cated inside the unit for protection against damage. The con-
denser coil is internally mounted on the top tier of the unit.
Copper fin coils and pre-coated fin coils are available from the
factory by special order. These coils are recommended in appli-
cations where aluminum fins are likely to be damaged due to
corrosion and are ideal for seacoast applications.
UNIT 582A
Page view 0
1 2 ... 24

Summary of Contents

Page 1 - Sizes 018-060

SINGLE-PACKAGEGAS HEATING/ELECTRICCOOLING UNITS Model 582ASizes 018-060 1-1/2 to 5 Nominal TonsLow NOx Models AvailableForm No. PDS 582A.18.2 Single

Page 2 - FEATURES/BENEFITS

SELECTION PROCEDURE (with example)I DETERMINE COOLING AND HEATING REQUIRE-MENTS AT DESIGN CONDITIONS:Given:Required Cooling Capacity (TC) ...

Page 3 - ARI* CAPACITIES

PERFORMANCE DATANET COOLING CAPACITIES582A018TEMP (F)OUTDOOR-AIRENTERINGCONDENSEREVAPORATOR AIR—CFM/BF525/0.118Evaporator Air—Ewb (F)62 67 72 62 67

Page 4 - PHYSICAL DATA

PERFORMANCE DATA (cont)NET COOLING CAPACITIES (cont)582A036TEMP (F)OUTDOOR-AIRENTERINGCONDENSEREVAPORATOR AIR—CFM/BF1050/0.095Evaporator Air—Ewb (F)

Page 5 - OPTIONS AND ACCESSORIES

PERFORMANCE DATA (cont)NET COOLING CAPACITIES (cont)582A060TEMP (F)OUTDOOR-AIRENTERINGCONDENSEREVAPORATOR AIR – CFM/BF1750/0.039Evaporator Air – Ew

Page 6 - Economizer

PERFORMANCE DATA (cont)DRY COIL AIR DELIVERY*—HORIZONTAL AND DOWNFLOW DISCHARGE(Deduct 10% for 208 v)230 AND 460 VOLTUnit582AMotorSpeedExternal Stat

Page 7

PERFORMANCE DATA (cont)ECONOMIZER/1-IN. FILTER PRESSURE DROPUNIT 582APRESSURE DROP(in. wg)018-042 0.12048, 060 0.24WET COIL PRESSURE DROPUNIT 582A A

Page 8 - FLUE HOOD

TYPICAL PIPING AND WIRINGVertical Discharge*NEC – National Electrical CodeHorizontal Discharge16INDOORTHERMOSTATDISCONNECTPER NEC*FROMPOWERSOURCERET

Page 9

17 APPLICATION DATA 1. CONDENSATE TRAP —A 2-in. condensate trap must befield supplied. 2. DUCTWORK —Secure downflow discharge ductwork toroof curb. For

Page 10

TYPICAL WIRING SCHEMATIC, 582A018-060; 208/230-1-60LEGENDBR — Blower RelayC—ContactorCAP — CapacitorCOMP — Compressor MotorCR — Combustion RelayEQUI

Page 11 - NET COOLING CAPACITIES

TYPICAL WIRING SCHEMATIC, 582A030-060; 208/230-3-60LEGENDAHA — Adjustable Heat AnticipatorBR — Blower RelayC—ContactorCAP — CapacitorCOMP — Compress

Page 12 - NET COOLING CAPACITIES (cont)

2 Low Sound Ratings ensure a quiet indoor and outdoor environ-ment with sound ratings as low as 7.5 bels. (See ARI capacitycharts for individual val

Page 13

TYPICAL WIRING SCHEMATIC, 582A036-060; 460-3-60LEGENDAHA — Adjustable Heat AnticipatorBR — Blower RelayC—ContactorCAP — CapacitorCOMP — Compressor M

Page 14 - (Deduct 10% for 208 v)

ELECTRICAL DATAUNITSIZE582AV-PH-HzVOLTAGERANGECOMPRESSORCOND FANMOTORINDOOR FANMOTORPOWER SUPPLYMin Max RLA LRA FLA FLA MCA MOCP*018 208/230-1-60 18

Page 15 - HIGH ALTITUDE COMPENSATION

CONTROLSOPERATING SEQUENCEHeating — When the thermostat calls for heating, terminal “W”is energized, starting the induced-draft motor. When the hall

Page 16 - Horizontal Discharge

GUIDE SPECIFICATIONSPACKAGED HEATING/COOLING UNITSCONSTANT VOLUME APPLICATIONHVAC GUIDE SPECIFICATIONSSIZE RANGE: 11/2TO 5 TONS, NOMINAL COOLING40,0

Page 17 - APPLICATION DATA

GUIDE SPECIFICATIONS (cont)K. Electrical Requirements:All unit power wiring shall enter the unit cabinet at asingle location.L. Motors:1. Compresso

Page 18

ARI* CAPACITIESCOOLING CAPACITIES AND EFFICIENCIESUNIT 582A NOMINAL TONS STANDARD CFMNET COOLINGCAPACITIES (Btuh)SEER†SOUND RATINGS**(Bels)018040 11

Page 19

PHYSICAL DATAUNIT SIZE 582A 018040 024040 024060 030040 030060 036060 036090 042060 042090NOMINAL CAPACITY (ton) 11/22221/221/23331/231/2OPERATING W

Page 20

OPTIONS AND ACCESSORIESFACTORY-INSTALLED OPTIONSLouvered Grille provides hail guard and vandalism protection.A wire grille is standard on all models

Page 21 - ELECTRICAL DATA

OPTIONS AND ACCESSORIES (cont)EconomizerDAMPERBLADEMANUAL OUTSIDEAIR HOODREPLACEMENTPANELFilter Rack Manual Outdoor Air Damper6

Page 22 - CONTROLS

BASE UNIT DIMENSIONS – 582A018-042REQ'D CLEARANCES FOR OPERATION AND SERVICING. in. (mm)Evaporator coil access side ...36(914)Po

Page 23 - GUIDE SPECIFICATIONS

BASE UNIT DIMENSIONS – 582A048-060FLUE HOODREQ'D CLEARANCES FOR OPERATION AND SERVICING. in. (mm)Evaporator coil access side ...

Page 24 - GUIDE SPECIFICATIONS (cont)

ACCESSORY DIMENSIONSUNIT SIZE582AODS ORDER NUMBERAin. [mm]Bin. [mm]Cin. [mm]Din. [mm]FLATCURB018-042CPRFCURB006A00 8 [203] 1127/32[301] 305/8[778] 2