TYPICAL WIRING SCHEMATIC, 582A018-060; 208/230-1-60
LEGEND
BR Blower Relay
C—Contactor
CAP Capacitor
COMP Compressor Motor
CR Combustion Relay
EQUIP Equipment
FS Flame Sensor
FU Fuse
GND Ground
GVR Gas Valve Relay
HS Hall Effect Sensor
HV High Voltage Transformer
TRAN
I—Ignitor
IDM Induced-Draft Motor
IFM Indoor-Fan Motor
IGC Integrated Gas
Unit Controller
LS Limit Switch
MGV Main Gas Valve
NEC National Electrical Code
OFM Outdoor-Fan Motor
QT Quadruple Terminal
RS Rollout Switch
ST Thermistor Start
TRAN Transformer
Field Splice
Terminal (Marked)
Terminal (Unmarked)
Splice
Splice (Marked)
Factory Wiring
Field Control Wiring
Field Power Wiring
Accessory or
Optional Wiring
To Indicate Common
Potential Only: Not to
Represent Wiring
NOTES:
1. If any of the original wires furnished are replaced, they must be re-
placed with type 90 degree C wire or its equivalent.
2. See price pages for thermostat and subbases.
3. Use 75 degree C copper conductors for field installation.
4. For high speed IFM, disconnect RED wire from IGC:BM and connect
BLK wire from IFM. For medium speed, disconnect RED wire from
IGC:BM and connect BLU wire from IFM.
5. Models 582A018-042 have LS1 and LS2 wired in series.
Models 582A048,060 have LS1 only.
18