Bryant 619MNC User Manual

Browse online or download User Manual for Split-system air conditioners Bryant 619MNC. Submittal Data [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Submit ta l Data
538MNC018 WITH 619MNC018
LEGACY LINEt HIGH--WALL DUCT--FREE SPLIT SYSTEM
COOLING ONLY WITH PURONr REFRIGERANT
Job Data:_________________________________________________ Location:________________________________________
Buyer:________________________________________ Buyer P.O.#_______________________ Carrier # _________________
Unit Number:__________________________________ Model Number: _____________________________________________
Performance Data Certified By: _________________________________________ Date: _______________________________
the environmentally sound refrigerant
FEATURES
S
13 SEER
S Wireless remote standard
S Low voltage controls
S User selectable fan speeds (auto, low med., high)
S Indoor unit is powered from the outdoor unit
S Auto restart
S Diagnostics
S Dehumidification mode
S Sleep mode
S Auto swing
S Timer
S Cleanable filters
S Low ambient operation to -- 20_F (-- 28.9_C) with
accessories
Indoor Unit -- 619MNC / Outdoor Unit -- 538MNC
(Unless otherwise indicated, data applies to both indoor and outdoor models)
SYSTEM SIZE 018...........................................
REFRIGERANT R--410A......................................
PERFORMANCE
Nominal Capacity 18,000....................................
SEER 13..................................................
Airflow (Low/Med/High) 500 / 570 / 630.........................
Performance at actual conditions: Attached j Not Attached j
SOUND PRESSURE dBA
Indoor (Low/Med/High) 43 / 45 / 48............................
Outdoor 57................................................
SOUND POWER dBA
Indoor (Low/Med/High) 54 / 56 / 59............................
Outdoor 68................................................
ELECTRICAL
System Voltage 208/230V.....................................
MCA (outdoor) 11..........................................
MOCP (outdoor) 20.........................................
Fan Motor (Indoor) (FLA) .26.................................
Motor Watts 31.............................................
CONTROLS
Control Remote Wireless.....................................
Control Voltage Low Voltage.................................
Interconnecting (indoor to outdoor) Wiring (0-- 50 ft.) 18 AWG........
Interconnecting (indoor to outdoor) Wiring (50--65 ft.) 16 AWG.......
REFRIGERANT LINES (Insulate both lines)
Mixed Phase Line (in.) OD 1/4................................
Vapor Line (in.) OD 1/2.....................................
Metering/Control Device Capillary tube in outdoor unit.............
Condensate Pump: Required j Not Required j
Low Ambient Controls: Required j Not Required j
Crankcase Heater: Required j Not Required j
Wind Baffle: Required j Not Required j
Optional:
Compressor extended warranty 6--10 years: Required j Not Required j
All parts & labor 2 --5 years: Required j Not Required j
All parts & labor 2 --5 years + Compressor 6 --10 years: Required j Not Required j
Page view 0
1 2

Summary of Contents

Page 1 - Submit ta l Data

Submit ta l Data538MNC018 WITH 619MNC018LEGACY LINEt HIGH--WALL DUCT--FREE SPLIT SYSTEMCOOLING ONLY WITH PURONr REFRIGERANTJob Data:__________________

Page 2 - Air Flow

2UNIT DIMENSIONS --- INDOOR MODELModel SizeWin. (mm)Hin. (mm)Din. (mm)OperatingWeightlb (kg)18K49.21(1250)12.80(325)9.06(230)36.4(17)A07336Fig. 1 – 61

Comments to this Manuals