Bryant SYSTXBBECW01 Instruction Manual Page 60

  • Download
  • Add to my manuals
  • Print
  • Page
    / 100
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 59
50
A12194
S Airflow: Selectable from Off to Max in 50 CFM increments
d Off = 450 CFM, MAX = (odu_size in KBTU * 400) / 12)
d Default = Off
NOTE: Selected airflow used during hydronic heating is a fixed value, it does not
vary.
S Blower On Delay: Selectable from 0 to 240 seconds
d Default = 30 seconds
S Blower Off Delay: Selectable from 0 to 240 seconds
d Default = 0 seconds
6.4. Check out
Touch CHECKOUT to view the equipment installed in the system. Perform
checkout test to make sure each piece of equipment is operating properly.
Page view 59
1 2 ... 55 56 57 58 59 60 61 62 63 64 65 ... 99 100

Comments to this Manuals

No comments